Sale!

Eastman ESP5K 5000VA Solar Off Grid PWM PCU

390,000.00

Product Details Product Specification Weight 47kg Model No ESP5K/48 Grid Charging Current Low 18 Amp (TUB, FL, GEL, SMF) PCU 5000 VA Boost Voltage 57.6 V/56.8 V/56.8 V/56.8 +/- 0.4 V (TUB, FL, GEL, SMF) Float Voltage 55.2 V/54.4 V/55.2 V/55.2 +/- 0.4 V (TUB, FL, GEL, SMF) Change Over Time Normal Mode Less than 50 ms (Mains-PCU) Change Over Time UPS Mode Less than 10 ms (Mains-PCU/PCU-Mains) Output Voltage Regulation AC from Min to Max Battery Voltage and No Load to Full Load 195 V-230 V Nominal Input Battery Voltage DC 48 V Battery Low Voltage Warning 43.2 V+/- 0.8 V Mains AC High Cut UPS Mode 265 +/- 10 V Battery Low Voltage Cut 42 V +/- 0.8 V Load Reconnect Voltage 50.8 +/- 0.8 V Short Circuit Protection Provided Maximum Input PV Voltage 90 V Over Load Protection 6 Sec. (125%) Over Temp Protection Through Cooling Fan Max Solar Panel Wattage UP to 4 Kwp Battery Charging Current Imax 20 Amp (From Solar+Grid) Protection Over Current, Battery Over Charge, PV Reverse Polarity, Reverse Current Flow Display Type LCD Display Mains AC High Cut Recovery UPS Mode 255 +/- 10 V Mains AC Low Cut UPS Mode 180 +/- 10 V Mains AC Low Cut Recovery UPS Mode 190 +/- 10 V Mains AC Low Cut Normal Mode 100 +/- 10 V Mains AC Low Cut Recovery Normal Mode 110 +/- 10 V Mains AC High Cut Normal Mode 280 +/- 10 V Mains AC High Cut Recovery Normal Mode 270 +/- 10 V
Eastman ESP5K 5000VA Solar Off Grid PWM PCU
Category:

Description

Product Specification

Weight 47kg
Model No ESP5K/48
Grid Charging Current Low 18 Amp (TUB, FL, GEL, SMF)
PCU 5000 VA
Boost Voltage 57.6 V/56.8 V/56.8 V/56.8 +/- 0.4 V (TUB, FL, GEL, SMF)
Float Voltage 55.2 V/54.4 V/55.2 V/55.2 +/- 0.4 V (TUB, FL, GEL, SMF)
Change Over Time Normal Mode Less than 50 ms (Mains-PCU)
Change Over Time UPS Mode Less than 10 ms (Mains-PCU/PCU-Mains)
Output Voltage Regulation AC from Min to Max Battery Voltage and No Load to Full Load 195 V-230 V
Nominal Input Battery Voltage DC 48 V
Battery Low Voltage Warning 43.2 V+/- 0.8 V
Mains AC High Cut UPS Mode 265 +/- 10 V
Battery Low Voltage Cut 42 V +/- 0.8 V
Load Reconnect Voltage 50.8 +/- 0.8 V
Short Circuit Protection Provided
Maximum Input PV Voltage 90 V
Over Load Protection 6 Sec. (125%)
Over Temp Protection Through Cooling Fan
Max Solar Panel Wattage UP to 4 Kwp
Battery Charging Current Imax 20 Amp (From Solar+Grid)
Protection Over Current, Battery Over Charge, PV Reverse Polarity, Reverse Current Flow
Display Type LCD Display
Mains AC High Cut Recovery UPS Mode 255 +/- 10 V
Mains AC Low Cut UPS Mode 180 +/- 10 V
Mains AC Low Cut Recovery UPS Mode 190 +/- 10 V
Mains AC Low Cut Normal Mode 100 +/- 10 V
Mains AC Low Cut Recovery Normal Mode 110 +/- 10 V
Mains AC High Cut Normal Mode 280 +/- 10 V
Mains AC High Cut Recovery Normal Mode 270 +/- 10 V

Product Description

Features:

  • Pure sinewave output
  • Advanced DSP based Technology
  • LCD screen for user convenience
  • Solar energy usage always on first priority
  • Intelligent mixing of grid current with solar in case of solar energy shortfall during cloudy days
  • Highest efficiency in its class
  • Can work as normal inverter if solar panels are not installed
  • Completely Safe: Overload Protection, Short Circuit Protection, Battery & PV Reverse Connection Protection